0 item(s) - Rs. 0.00

Customer Helpline : 1860 2081 007 (10:00AM - 7:00PM)

0 item(s) - Rs. 0.00

Find My AC

Inverter Multi








Compact size panel design that fits standard ceiling panel (600x600mm)  
Inverter Multi

Availability: In stock

50000 Rs 50,000.00
Enquire Now

Details

System configuration example

This system is used for small and medium-sized buildings.
1 refrigerant system is used for each outdoor unit.
Single piping. Single outdoor unit.
Connection of upto 9 indoor units using separation tubes.
One refrigerant circuit for one electrical circuit.
Electrical circuit for each air conditioning system should be independent.

Features

Most building loads are in the range of almost 40% to 80%. Therefore, most air conditioners do not operate at maximum load, but operate at low to medium loads. Especially, for multi system, operation performance at partial load is important because all the air conditioners do not always operate all the time. Aiming at energy saving performance matched to actual operation, Fujitsu General has developed a high intermediate performance air conditioner corresponding not only to the rated performance at 100% load,

Load curve (a typical ofce building)

Conditions :

Connected indoor units:

AUXA30GALH + AUXD24GALH

Cooling:

indoor temp. of 27°CDB / 19°CWB, outdoor temp. of 35°CDB / 24°CWB

Heating:

indoor temp. of 20°CDB / 15°CWB, outdoor temp. of 7°CDB / 6°CWB

Long Piping Length

Our advanced refrigerant control technology allows us to achieve a total refrigerant piping length of 180 m. This opens up new possibilities in the system design.

Advanced high-efciency technology

Compact Cassette

Compact size panel design that fits standard ceiling panel (600x600mm)

2-Stage Turbo fan

High-efciency design by 2 stage structure

Quiet Quality

Optimization of wing form (laminar wing type) and wing number (7 blades each)

Designed by CFD-analysis (fluid) simulations


An evenly spread air distribution acrossthe heat exchanger is possible due to the new 2 stage turbo which produces two seperate airflow streams



High-Lift Drain Pump


Compact Design

Easy installation by taking off ceiling panel of 600 x 600 size.

 High Ceiling Mode

This cassette can be installed up to a height of 3.0m (12).

 

 

Large Cassette

Powerful, wide airflow and quiet operation.

High-efciency Turbo Fan with 3-Dimensional Blade

High-efficiency airflow distribution has been achieved by the introduction of a 3 dimensional blade which increases the air passing over the heat exchanger


Duct Connection Hole Opening

Conditioned air can be distributed by means of a distribution duct.


Improvement of The Airow Distribution

The louvre design distributes air
leaving a space between the
chassis and theceiling allowing far
and wide air flow distribution.

 

High Ceiling Mode


Slim Duct

Slim design and wide range of static pressure for flexible installation.

Slim Design

With a slim indoor design, this indoor can
be installed in narrow ceiling spaces.


Air-Intake

Air intake direction can be selected
to match the installation site.


High Lift Drain Pump

With a slim indoor design, this indoor can
be installed in narrow ceiling spaces.


Selectable with a Wide Range of Static Pressure

By using DC fan motor, it is possible to change of
static pressure range 0 to 90Pa.


Flexible Installation

 

 


Medium Static Pressure Duct

Slim Compact design allows for easy installation in narrow ceiling spaces up to 270mm

Slim & Compact design

In the case of bottom return air connection, not
only does the indoor unit design allow for
installation in a narrow ceiling space of up to
270mm, Further space savings have been
achieved by mounting the electrical control box
internally inside the chassis.




Line-Up Of Low-Noise And
High-Power Models, Compatible With
a Wide Range of Static Pressure

Powerful Model With a Fexible Design

With a powerful motor, appropriate for a wide range of static pressure.
Flexible air duct installation is possible in a large space such as an office.


Easy Maintenance

Structural improvement is attained by
making the bottom panel two pieces,
front and rear. The internal fan casing is
also manufactured in two pieces, namely
upper and lower. The maintenance of the
motor and fan can be easily carried out
by removing the rear panel and the
lower part of the casing while leaving

 

 

 


Two-Direction 

Drain Piping

 

 

 

Installation styles

 Embedded in Ceiling                    Hanging from Ceiling

Optional parts

Drain Pump Unit : UTZ-PX1NBA in case if drain lift is required,
else drain is by gravity only


Wall Mounted

ASHA07GACH/12GACH

Compact and Stylish Design

ASHA18GACH/24GACH

Simple Elegant Appearance Design

Powerful and Compact

Though the indoor unit is compact, it features a large, high pressure cross fan (90mm diameter) in a centre mounted
configuration and a Lambda type heat exchanger to provide plenty of power.

Advanced Airow Technology by Specially Designed Power Diffuser

The cold air discharged is directed upward by the specially designed large power diffuser, which achieves the Coanda airflow up to 15m.

“Vertical airow” provides powerful oor level heating

 

“Horizontal airow” does not blow cool air directly at the occupants in the room

New style high power DC fan motor

• High power

• Wide rotation range

• High efficiency

• Compact size

Long reach airow         

                                                       (18/24)

3D Double auto swing

A combination of up/down and right/left directional swing allows
three-dimensional air direction control (18/24).


Wirless Remote Controller

UTY-LNHG

Simple and sophisticated

operations with a choice of

4 daily timers

• A single controller controls

up to 16 indoor units.

 

 

Features


.

Functions

Built-In Daily Timer

Select from 4 different timer programs :

On / Off / Program / Sleep

Program timer : The program timer operates the ON and OFF
timer once within a 24 hour period.

Sleep timer : The sleep timer function automatically corrects the
set temperature according to the time setting to prevent excessive
cooling or heating during sleep hours.

 

Specications

 

 

IR Receiver Unit

UTB-YWC

Necessary to control for all duct type by
Wireless Remote Controller

• Up to 16 indoor units can be controlled with one remote controller.
• Suitable for hotels or offices as it is easily operated with no complex functions.

Wiring connection

 

 

 

 

Duct Type Indoor Unit

 

IR Receiver Unit

UTY-LRHGB1

Cassette type indoor unit can be controlled
with Wireless Remote Controller

Specications

.

Separation Tube

Connection Units



Transmission Cable

● Belden Transmission Cable 7703NH.00C305
● 2 Core/22 AWG
● Seamless communication cable in series connection




Compact Cassette

Model NameAUXB07GALHAUXB12GALH
Rating Capacity Tonnage TR 0.6 1.0
Power Supply V/ Ø /Hz - 230/1/50
Rated Capacity Cooling BTU/hr 7500 12280
kW 2.2 3.6
Heating BTU/hr 9500 13980
kW 2.8 4.1
Input Power - W 25 29
Airflow High m3/h (cfm) 540(317) 600(353)
Med 450(264) 530(311)
Low 350(206) 390(229)
Noise Level High dB(A) 34 37
Med 30 34
Low 25 27
Dimensions H x W x D mm 245 x 570 x 570
Net Weight - kg 15
Piping Copper - Hard Drawn
Connection Method - - Flare
Connection Pipe Diameter Gas, Liquid inch 1/2" , 1/4"
Cassette Girlle Dimensions (H x W x D) mm 50 x 700 x 700
Cassette Girlle Net  Weight - kg 2.6
Operating Temperature Cooling °c -5 to 46
Heating °c -20 to 21

Large Cassette

Model NameAUXD18GALHAUXD24GALHAUXD30GALHAUXD36GALHAUXD54GALH
Rating Capacity Tonnage TR 1.5 2.0 2.5 3.0 4.0
Power Supply V/ Ø /Hz - 230/1/50
Rated Capacity Cooling BTU/hr 19100 24220 30700 38210 47760
kW 5.6 7.1 9.0 11.2 14
Heating BTU/hr 21490 27290 34120 42650 54590
kW 6.3 8.0 10.0 12.5 16.0
Input Power - W 39 46 59 80 119
Airflow High m3/h (cfm) 1150 (676) 1280 (753) 1600 (941) 1800 (1059) 2000 (1177)
Med  940(553) 1040 (612)  1300 (765) 1370 (765) 1370 (806)
Low 870 (512) 870(512) 1100(647) 1100(647) 1100(647)
Noise Level High dB(A) 36 38 40 44 47
Med 30 33 38 38 39
Low 29 29 33 33 33
Dimensions H x W x D mm 246 x 840 x 840 288 x 840 x 840
Net Weight - kg 22 27
Piping Copper - Hard Drawn
Connection Method - - Flare
Connection Pipe Diameter Gas, Liquid inch 1/2" , 1/4" 5/8" , 3/8"
Cassete  Grille Dimensions H x W x D mm 50 x 950 x 950
Cassete  Grille Net Weight - kg 5.5
Operating Temperature Cooling °C -5 to 46
Heating °C -20 to 21

Slim Duct

Model NameARXD12GALHARXD18GALHARXD24GALH
Rating Capacity Tonnage TR 1.0 1.5 2.0
Power Supply V/ Ø /Hz - 230/1/50
Rated Capacity Cooling BTU/hr 12280 19100 24220
kW 3.6 5.6 7.1
Heating BTU/hr 13640 21490 27290
kW 4.0 6.3 8.0
Input Power - W 54 83 122
Airflow High m3/h (cfm) 600(353) 940(553) 1330(782)
Med 510(300) 840(494) 1240(729)
Low 450(264) 750(441) 1100(647)
Static Pressure Range - Pa 0 to 90 0 to 50
Standard Static Pressure - 25
Noise Level High dB(A) 30 34 35
Med 27 32 32
Low 24 28 29
Dimensions H x W x D mm 198 x 700 x620 198 x 900 x620 198 x 1100 x620
Net Weight - kg 18 22 26
Piping Copper - Hard Drawn
Connection Method - - Flare
Connection Pipe Diameter Gas, Liquid inch 1/2" , 1/4" 5/8" , 3/8"
Operating Temperature Cooling °C -5 to 46

Heating

°C -20 to 21

Medium Static Pressure Duct Slim Duct

Model NameARXA24GALHARXA30GALHARXA30GALHARXA45GALH
Rating Capacity Tonnage TR 2.0 2.5 3.0 3.5
Power Supply V/ Ø /Hz - 230/1/50
Rated Capacity Cooling BTU/hr 24220 30700 38210 42650
kW 7.1 9.0 11.2 12.5
Heating BTU/hr 27290 34120 42650 47760
kW 8.0 10.0 12.5 14.0
Input Power - W 190 188 312 312
Airflow High m3/h (cfm) 1280(753) 1720(1012)
Med 1210(300) 1670(982)
Low 1130(665) 1600(941)
Static Pressure Range - Pa 30 to 150
Standard Static Pressure - 100
Noise Level High dB(A) 38 40 43
Med 36 38 41
Low 34 36 39
Dimensions H x W x D mm 270 x 1135 x 700
Net Weight - kg 39 42
Piping Copper - Hard Drawn
Connection Method - - Flare
Connection Pipe Diameter Gas, Liquid inch 5/8" , 3/8" 3/4" , 3/8"
Operating Temperature Cooling °C -5 to 46

Heating

°C -20 to 21

Wall Mounted

Model NameASHA07GACHASHA12GACHASHA18GACHASHA24GACH
Rating Capacity Tonnage TR 0.6 1.0 1.5 2.0
Power Supply V/ Ø /Hz - 230/1/50
Rated Capacity Cooling BTU/hr 7500 12280 19100 24220
kW 2.2 3.6 5.6 7.1
Heating BTU/hr 9550 13980 21490 27290
kW 2.8 4.1 6.3 8.0
Input Power - W 17 22 32 60
Airflow High m3/h (cfm) 490(288) 560(329) 840(494) 1100(647)
Med 450(264) 480(282) 770(453) 910(535)
Low 420(247) 420(247) 690(406) 730(429)
Noise Level High dB(A) 35 39 41 48
Med 33 35 39 43
Low 31 31 35 35
Dimensions H x W x D mm 275 x 790 x 215 320 x 998 x 228
Net Weight - kg 9 15
Piping Copper - Hard Drawn
Connection Method - - Flare
Connection Pipe Diameter Gas, Liquid inch 1/2" , 1/4" 5/8" , 3/8"
Operating Temperature Cooling °C -5 to 46

Heating

°C -20 to 21

Attention Customers : We have not authorised any E-commerce site to sell our products. To buy General Air conditioners online, please visit our e-Shop at www.generalindia.com

Template Settings
Select color sample for all params
default
blue
brown
cyan
Red
Background color
Text color
Body font-size